Home Products Liftparker N 4600

 
 

Revised design of the traditional solution

Both platforms horizontal accessible. The comfort solution with offset columns.

 

Construction & Design for
Small-sized car parks
Carports
Back yard areas
Underground Car Parks

Function

Internal comparison

Comfort without compromise
Vehicle restrictions

*****
*****

Identification Figures

RL/space: Required room per lot

> 32m (cubed)

AS/space: Area space per lot

> 6,5m (squared)

CFR: Cost factor relation per lot
(comparative & system Ð related)

> 19unit

Revised design of the traditional solution with offset columns for ceiling heights of more that 3mt,

Features & Options

Scope of supply
* Options



Features of the Liftparker N 4600 E/D

*Key switch include. Emergency stop, dead mans control with brief operating instructions and wiring to aggregate.
*“Lockable key switch” – Key is extracted from switch only when the installation is lifted.
*S/d-ins installations with 2 platforms, 2 column assemblies c/w hydraulic cylinder, lifting carriage and hydraulic unit
*Width of lot modified to 240cm and depth of pit 170/165cm as standard
*Width of lot modified to 240cm and wider or PD 185/180 and deeper recommended for higher car accessibility and convenience
*Synchronizing device to improve operation with unequal load distribution
*Entering wedge for car positioning
*Safety device to prevent from lowering in case of pipe fracture

*Mounting of installation and aggregate with HD – anchors, wiring with impact dowels
*Bound anchors for increased foundation requirements

*Drive unit “Silencio” with tubing and wiring to the installation
*Hydraulic package “ parallel operation”: Simultaneous lifting of 2 or more installations per aggregate at given pump capacity, or simultaneous lowering respectively
*Structure-born noise package to comply with DIN4109 and adherence to sound insulation measure Rw ’55
*Sound installation hood to minimize airborne sound
*HVLP-oil for excessive functions in temperature

*Drive plates in trapezoid style sheeting
*Rubber profiles in the pedestrian area, width 40cm or 60cm, in pedestrian and drive area 60cm and 40cm
*Luxury sheet metal only for horizontal lots
*Corrosion prevention “ Classic” of drive plates by continuous line-galvanizing to DIN EN 10142/10143
*Corrosion prevention “Premium” of drive plates by individual piece – galvanizing to DIN ISO 1461
**Corrosion prevention “Classic Plus” of drive plates by line-galvanizing to DIN EN 10142/10143 and coating of the top surfaces (dependant on the market needs the scope of supply contains zinced and powder coated sheet metal)
*Corrosion prevention “Premium Plus” of the driving plates by individual piece galvanizing to DIN ISO 1461 and coating of the top surfaces

*Railings to risk of falling onto the platform, insofar as necessary (Note: Safe guarding against sheering and squeezing have priority and must be provided by the proprietor)Ramps when door facing is not available to install the door slide rail, pit length must be 525cm, at the minimum.
*Vehicle load: 2.0 to length: 5 m, as per vehicle data
Extra capacity of upper platform to 2.5 to, vehicle length up to 5.20m
*A maintenance contact is recommended
*Attendance and cleaning to requirements or at regular intervals is recommended

 

Intersections / Costumers duties

Intersections / Costumers duties
Lockable main switch, near to aggregate, completed at the beginning of erection
Capacity of aggregate: 400V, 50Hz, three phase motor 3,0kw
Supply line to main switch 5 x 1,5mm2, or to local regulations, fuse protection 3 x 16 amp, slow
Electrical potential equalization (foundation grounding steel0-construction to VDE 0100 T410)
Level surface (L x W) 50cm x 20cm to attach the control unit, adjacent to the installation, outside the operational platform area
Safeguarding to DIN 294
Lighting to DIN 6758, illumination of parking lots and buildings for parking
Foundation exactly to size, clean and dry
Compliance with installation requirements as per quotation
The measurements are minimum finished dimensions. Tolerance to VOB, part C (DIN 18330, 18331) should be considered supplementary. Measurements in cm.

 

Foundation Plan

The pit must be executed in compliance with the designed forces. All forces are led into the ground via bearing plates of a minimum area 150cm squared. The bearing plates are fixed with metal straddling dowels. The drill hole depth is approx. ca. 14cm. All walls in the pit below the entrance level must be concrete.

 

Technical alterations reserved. Alterations in the scope of supply reserved. Version 16/2006

 

Vehicle Data

Weight Max. 2000kg, wheel load max 500kg, platform above and below: car-height H

Option Version S-Klasse, vehicle length 510cm

Weight Max. 2500kg, wheel load max. 625kg only on s-installation above, width of space S = 250/260/270cm, width of system B = 280/290/300cm, length of pit: 540cm

 


Measurements, Engineering & Design

Revised design of the traditional solution for ceiling heights of more that 3mts! Both platforms horizontal accessible. The comfort solution with offset columns.

 



System Variations

 

 

 

 

car height, above & below, id figures

 

GV

GH

LH

SH

H

H

R/L

CFR

A/S

Liftparker N 4600

170

165

325

390

150

150

32

19

6.5

 

185

180

340

420

165

155

33

20,5

6,5

 

185

180

350

420

165

155

33

20,5

6,5

 

200

195

350

450

180

150

34

22

6,5

 

200

195

380

450

180

180

37

22

6,5

 

225

220

430

500

205

 

 

 

 

 

System Width

 

 

 

 

 

R/L, CFR, A/S, id figures

S

B

R/L

CFR

A/S

Liftparker N 4600 S

230

260

34

24

6,9

 

240

280

36

25

7,2

 

250

280

37

26

7,4

Liftparker N 4600 D

230x2

490

32

19

6,5

 

240x2

510

34

20

6,8

 

250x2

530

35

21

7,0

 


Layout A: partition walls/no supporting pillars in or in front of pit.
S=single installation, D=double installation S+D installation

Width Platform

Width Platform

Width Platform

 

A1

Width

a1

Width

A1

Width

Liftparker N 4600

260

230

490

460

750

460/230

 

270

240

510

480

780

480/240

 

280

250

530

500

810

500/250

 

Layout B: supporting pillars inside of pit.
S=single installation, D=double installation E+D installation

 

Width Platform

Width Platform

Width Platform

Liftparker N 4600

B1

B2

Width

B1

B2

Width

B1

B2

Width

 

255

250

230

485

475

460

745

735

460/230

 

265

260

240

505

495

480

775

765

480/240

 

275

270

250

525

515

500

805

795

500/250

 

Layout C: supporting pillars in front of pit.
S=single installation, D=double installation S+D installation

Liftparker N 4600

Width

Width

Platform

Width

Width

Platform

Width

Width

Platform

 

C1

C2

Width

C1

C2

Width

C1

C2

Width

 

250

240

230

480

470

460

740

730

460/230

 

260

250

240

500

490

280

770

760

480/240

 

270

260

250

520

510

500

800

790

500/250

 

 


 

Products

2 Park
Duplex
B-Power
Kipparker N 3000
Liftparker N 4100
Liftparker N 4400
Parkline N 5001
Uniparker N 5002
Uniarker N 5003
Intergrated Solutions
Terrassparker T2
Smart-Tower Size L
Sliding Platform Transverse
Sliding Platform Longitude